Online medium range turbidity analyzer

Online medium range turbidity analyzer

The SYS-NM-3501 online medium range turbidity analyzer is a proprietary patented product specially designed for online monitoring of ordinary water. Featured with low turbidity detection limit, high measuring accuracy, long-term maintenance free, low water consumption, digital output, and support of remote data monitoring with the cloud platform and mobile app and of RS485-Modbus communication, it can be widely used for online monitoring of water turbidity in such applications as surface water, water plant raw water, recycled rain water, sewage treatment plant effluent and other recycled water.

0.00
0.00
  

The SYS-NM-3501 online medium range turbidity analyzer is a proprietary patented product specially designed for online monitoring of ordinary water. Featured with low turbidity detection limit, high measuring accuracy, long-term maintenance free, low water consumption, digital output, and support of remote data monitoring with the cloud platform and mobile app and of RS485-Modbus communication, it can be widely used for online monitoring of water turbidity in such applications as surface water, water plant raw water, recycled rain water, sewage treatment plant effluent and other recycled water.




Product Features:

◆   Excellent performance: Indication accuracy: 5%; lowest limit of detection: 0.02 NTU;

◆   Maintenance-free: Intelligent Sewage Method control &no need of manual maintenance; 

◆   Small: It is small-sized and especially suitable for system integration.

◆   Low water consumption: <250 ml/min;

◆   Network-based: It supports remote data monitoring with cloud platform and mobile app, and RS485-MODBUS communication.







Technical data:

◆   Size: 315 mm*165 mm*105 mm (H*W*T);

◆   Principle: 90º scattering;

◆   Working voltage: DC 24 V (voltage range: 19-30 V);

◆   Working mode: Intermittent flow real-time measurement;

◆   Measuring range: 0-100 NTU;

◆   Zero drift: ≤±0.1 NTU;

◆   Indication error: ≤±5% or ±0.5 NTU, whichever is higher;

◆   Sewage Method: Automatic;

◆   Method of calibration: Standard Formazin (calibrated before leaving the factory);

◆   Water consumption: An average of approx. 250 ml/min;

◆   Digital output: RS485 Modbus protocol (baud rate: 9600, 8, N, 1);

◆   Analog output: 4-20 ma;

◆   Storage temperature: -20 °C-60 °C;

◆   Working temperature: 5 °C-50 °C;

◆   Sensor material: Composite;

◆   Maintenance cycle: Maintenance-free. (It is subject to the specific water quality in special cases.)